Signal Conditioners, Temperature Transmitters and Controllers
Modbus RTU, Modbus TCP, Canbus, PLC's and Hmi's.
Call toll Free 1 887 877 4to 20mA or 1 877 486 2062
  • HMI withintegrated PLC.
  • TD240-11AD FEATURES

    • Thermocouple inputs.
    • 4-20mA inputs.
    • 0-10V inputs.
    • RTD inputs.
    • Potentiometer inputs.
    • 4-20mA Output.
    • 0-10V Output.
    • 16 Digital Inputs and Outputs.
    • Modbus
    • RS232, RS48 ports

HMI withintegrated PLC TD240-11AD

General Description

The TD240-11AD is a 3.5 inch Touch Screen HMI with a built in PLC. The TD240 can accept inputs from 4 analog sensors and 16 digital inputs. It also has 4 0-10Volt analog outputs and 16 solid state relays up to 700mA each.
The TD240-11AD can accept inputs from K type Thermocouples, S type Thermocouples, J type Thermocouples, T type Thermocouples, R type Thermocouples, E type Thermocouples. Pt100, Ni100, Pt1000 and Pt500 Resistance temperature detectors. NTC10K Ohm and PTC1 K Ohm Thermistors. 0-20mA, 4-20mA, 0-20mV, 0-1Volt and 0-10Volts.
The output is 0-10V 16 bit and can be set up as a control output with P, PI, PID or PD. Other function blocks include timers, up counters, down counters, mathematics, logic functions and rescale.
Programming is performed by the use of the PLprog software available free of charge and Ladder diagrams. It has both RS232 and RS485 serial ports and comes complete with a real-time clock and battery back up.
More analog and digital inputs and outputs can be added with the use of the MCM Data acquisition family of products.

INPUT
Thermocouple
RTD's, Thermistors
4-20Ma, 0-20mA.
0-20mV, 0-1V, 0-10V
OUTPUT
0-10V.

POWER SUPPLY
Power Supply Voltage
12...24 Vdc/VAC
POWER CONSUMPTION
8W MAX
CONFIGURATION
PLprog Software
ISOLATION
No.
EMC
For Industrial environments
Immunity EN 61000-6-2
Emission EN 6100-6-4
HOUSING
Dimensions W x H x T
5.5" x 3.9" x 2.6"
140 x 100 x 65mm
Weight 14 oz 460 g
TEMPERATURE
Operating Temperature 32°F +113°F 0°C +45°C
Humidity (non condensing) 35-95%

 

Specifications

Analog Input  
Thermocouples K,J, R, T, E and S Type
Current 0-20mA , 4-20mA.
Voltage 0-1Volt, 0-10Volt.
RTD's Pt100, Pt500, Pt1000, 500Ni.
Thermistors PTC, NTC
Digital Input 16 Digital inputs.
Analog Output  
Voltage 0-10Volts
Digital Output 16 Solid State Relays
Power Supply: 12...24Vac/Vdc.
Power Consumption: 4VA max.
Temperature Rating: Operative- 32°F +113°F -0°C +45°C
Humidity: (non condensing) 35-95%.
Housing: DIN Rail
Dimensions: 3.5" x 2.8" x 2.3", 90 x 71 x 58 mm
Weight: 14 oz 460 g
EMC. For industrial environments.
Immunity: EN 61000-6-2.
Emission: EN 61000-6-4.
Configuration: RS232, RS485.

Drawings

Power supply TD240-11AD TD240
Positive 12...24Vdc Terminal 3 Terminal 3
Negative Terminal 2 Terminal 2
Input and Output
Digital 1 Terminal 1
Digital 2 Terminal 2
Digital 3 Terminal 3
Digital 4 Terminal 4
Digital 5 Terminal 5
Digital 6 Terminal 6
Digital 7 Terminal 7
Digital 8 Terminal 8
Digital 9 Terminal 9
Digital 10 Terminal 10
Digital 11 Terminal 11
Digital 12 Terminal 12
Digital 13 Terminal 13
Digital 14 Terminal 14
Digital 15 Terminal 15
Digital 16 Terminal 16
Analog input  
Common Terminal 1/M4
AI.1 Input Terminal 1/M4
AI.2 Input Terminal 2/M4
AI.3 Input Terminal 3/M4
AI.4 Input Terminal 4/M4
Analog Output Terminal 5
AQ.1 Output Terminal 4/M3
AQ.2 Output Terminal 5/M3
AQ.3 Output Terminal 6/M3
AQ.4 Output Terminal 7/M3
Common Terminal 8/M3

HMI with PLC TD240


Communication TD240-11AD TD240
RS232 GND DB25 PIN14, DB9 PIN5. DB25 PIN14, DB9 PIN5.
RS232 RX DB25 PIN21, DB9 PIN7. DB25 PIN21, DB9 PIN7.
RS232 TX DB25 PIN22, DB9 PIN6. DB25 PIN22, DB9 PIN6.
RS485 GND DB25 PIN14, DB9 PIN5. DB25 PIN14, DB9 PIN5.
RS485 + DB25 PIN15, DB9 PIN9. DB25 PIN15, DB9 PIN9.
RS485 - DB25 PIN16, DB9 PIN4. DB25 PIN16, DB9 PIN4.

Applications

  • HMI with PLC TD240-11AD
Back to General Description HMI with PLC TD240-11AD.