Signal Conditioners, Temperature Transmitters and Controllers
Modbus RTU, Modbus TCP, Canbus, PLC's and Hmi's.
Call toll Free 1 887 877 4to 20mA or 1 877 486 2062
  • Panel meter STR550
  • Panel meter STR550 Green
  • STR560 FEATURES

    • Load Cell
    • Strain Gauge Input
    • 4-20mA Retransmission
    • 2 Relays
    • Data Logger
    • Modbus RTU Slave

Load Cell Panel Meter with OLED Display STR561

General Description

The OLED Display Load Cell Panel Meter STR561 is a load cell and strain gauge converter built into a 1/8 Din Panel Meter with a 48 x 48 mm size cut out. It can convert a load cell and strain gauge signal to 4-20mA and Modbus RTU and act as a Modbus Slave. The STR561 has a fast response time of 1200hZ that can be configured from 1 Hz to 1200 Hz. It can also display the trend on the OLED Display. The STR561 also has 2 relays and 2 digital inputs of which one can be an encoder. A 5 Vdc power supply is available for the excitation voltage for the strain gauge or load cell.
The STR561 has an isolated Modbus RTU slave output and an analog output which is 16 bit resolution and can be either 4-20mA or 0-20mA.

INPUT
Load Cell.
Strain Gauge.
OUTPUT
4-20mA.
0-20mA.
2 Relays 2 Amps.
Modbus RS485.

POWER SUPPLY
Power Supply Voltage
24 to 230 Vac Vdc
POWER CONSUMPTION
6W MAX
CONFIGURATION
Front panel Keyboard
LabSoftView
Memory Card
ISOLATION
Modbus Output
EMC
For Industrial environments
Immunity EN 61000-6-2
Emission EN 6100-6-4
HOUSING
Material self-extinguishing
Dimensions W x H x T
1.88 x 3.77 x 1.88" 48 X 96 X 48 mm
Weight 4 oz 165 g
TEMPERATURE
Operating Temperature 32°F +113°F 0°C +45°C
Humidity (non condensing) 35-95%

 

Specifications

Input
Load Cells Max 7.5 mV/V
Melt sensors Max 7.5 mV/V
Output: 2 X Relays 2 A. 250 V AC
Power Supply: 24 to 230Vac/Vdc.
Power Consumption: 6VA max.
Temperature rating: Operative- 32°F +113°F -0°C +45°C
Humidity: (non condensing) 35-95%.
Housing: Polycarbonate UL94V2 self-extinguishing
Dimensions: 1.88 x 3.77 x 1.88" 48 X 96 X 48 mm .
Weight: 5.3 oz 165 g.
EMC. For industrial environments.
  Immunity: EN 61000-6-2.
  Emission: EN 61000-6-4.
Configuration: PC Configurable, Memory Card

Drawings

STR550 Panel Meter wiring diagram
STR561-12ABC-T128 
Power supply 24-230V AC/DC
Live Terminal 5
Negative Terminal 6
Input
Excitation Voltage Positive 7
Negative 13
Load Cell Input Positive 143
Negative 14
Common 15
Digital input 1 Terminal 11
Digital input 2 Terminal 12
Retransmission 0/4-20mA
Positive Terminal 7
Negative Terminal 8
Retransmission 0-10V
Positive Terminal 9
Negative Terminal 8
RS485
Positive Terminal 16
Negative Terminal 17
Relay 1
Common Terminal 4
Normally Open Terminal 3
Relay 2
Common Terminal 2
Normally Open Terminal 1

Applications

  • OLED indication of Load Cell input.
  • Strain Gauge panel meter.
  • Load Cell to Modbus RTU.