Signal Conditioners, Temperature Transmitters and Controllers
Modbus RTU, Modbus TCP, Canbus, PLC's and Hmi's.
Call toll Free 1 887 877 4to 20mA or 1 877 486 2062
  • Panel Mount Counter
  • TCT101-2ABC FEATURES

    • UL, CE.
    • Counter
    • 2 x 4 Digit Display
    • Memory Card Programmable
    • Output 2 Relays 5 Amp

Panel Mount Counter TCT101-2ABC

General Description

The Panel Mount Counter TCT101-2ABC ia a panel mount digital programmerable Counter with the option of being a single or dual Counter. The TCT-2ABC is able to count upwards or count down and it is possible to lock the value or hold the value. The TCT101-2ABC has two line 4 digit displays and can be set up to switch on a relay after a certain amount of counts up or down. By selecting the keys or by a digital input it is possible to interrupt the counter.
Other options in the TCT101 series are:
The TCT101-1ABC also has two 4 digital displays and can be configured as a Timer.
The TCT101-3ABC is a Tachometer input indicating speed or frequency and can provide a digital output at a high speed.
The TCT101-4ABC-T is a combination containing a Timer, Counter and Tachometer and it also has a Modbus RS485 output.

INPUT
NPN, PNP, TTL.


OUTPUT
2 Relays 5 Amps.
POWER SUPPLY
Power Supply Voltage
24 to 230 Vac Vdc
POWER CONSUMPTION
3W MAX
CONFIGURATION
Front Panel Keyboard
LabSoftView
Memory Card
ISOLATION
No
EMC
For Industrial environments
Immunity EN 61000-6-2
Emission EN 6100-6-4
HOUSING
Material self-extinguishing
Dimensions W x H x T
3 x 1 3/8 x 2 1/8" 35 X 77 X 53 mm
Weight 4 oz 100 g
TEMPERATURE
Operating Temperature 32°F +113°F 0°C +45°C
Humidity (non condensing) 35-95%

 

Specifications

Digital Input NPN,PNP,TTL.
Potentiometer Input 5/10 K Ohms.
Output:
Relays Up to 2 Relays 5 A 250V AC
Power Supply: 24 to 230Vac/Vdc.
Power Consumption: 3VA max.
Temperature rating: Operative- 32°F +113°F -0°C +45°C
Humidity: (non condensing) 35-95%.
Housing: Polycarbonate UL94V2 self-extinguishing
Dimensions: 3 x 1 3/8 " x 2 1/8", 35 x 77 x 53 mm.
Weight: 4 oz 100 g.
EMC. For industrial environments.
  Immunity: EN 61000-6-2.
  Emission: EN 61000-6-4.
Configuration: PC Configurable, Memory Card

Drawings

Panel Mount Counter TCT101-2ABC wiring diagram
ATR101-2ABC 
Power supply
Live Terminal 1
Negative Terminal 2
Aux Power 24 V Terminal 9
0 V Terminal 8
Counter Input 1 Terminal 12
Counter Input 2 Terminal 11
Relay 1
Common Terminal 4
Normally Open Terminal 5
Normally Closed Terminal 3
Relay 2
Common Terminal 6
Normally Open Terminal 7

Applications

  • Process Counter.
Back to General Description Panel Mount Counter