Signal Conditioners, Temperature Transmitters and Controllers
Modbus RTU, Modbus TCP, Canbus, PLC's and Hmi's.
Call toll Free 1 887 877 4to 20mA or 1 877 486 2062
  • Single Phase Power Datalogger.
  • Single Phase Power Datalogger FEATURES

    • Single Phase Power Datalogger.
    • AC Voltage Datalogger.
    • AC Current Datalogger.
    • DC Voltage Datalogger.
    • DC Current Datalogger.
    • Freqquency Datalogger.
    • Energy kWh Datalogger.
    • Min and Max and pk Datalogger.

Single Phase Power Datalogger

General Description

The QA Power M is a Power meter with a built-in datalogger and Modbus RTU port that can log AC/DC Power, Current, Voltage, Frequency and kWh. It can accept Voltage up to 600V AC and 1000V DC and Current up to 10A direct or higher, with the use of current transformers. The QA Power M has both analog and digital outputs. The analog output can be either 4-20mA, 0-10V or 0-20mA. The digital is programmable to be either a pulse or an alarm output.
The QA Power M is programmable via the USB port or the RS485 port with the aid of the free software. The DIP switch is only usable for the Modbus address and Baud rate settings. The Datalogger information is stored on the USB flash drive.
The QA Power M logs the following to the USB Flash drive.

  • Voltage rms, Instantaneous Peak, Average, and Max.
  • Current rms, Instantaneous Peak, Average, and Max.
  • Power Active, Reactive, Apparent.
  • Frequency, Min, Max.
  • Total Harmonic Distortion.
  • Energy, Total, Positive, Negative.
  • Total Harmonic Distortion.
The unit is DIN Rail mounted. Set up is by either the DIP switches or by the free software available from our website. Isolation is provided up to 3000Volts on the Current input and 4 000 Volts on the Voltage input.

INPUT
Normal version 600VAC 1000VDC
Low Voltage version 60VAC 100VDC
OUTPUT
Modbus RTU.
4-20mA, 0-20mA, 0-10V.
USB Flash Drive.
POWER SUPPLY
Power Supply Voltage 10-40Vdc.
CURRENT CONSUMPTION
1.3 W.
CONFIGURATION
Modbus RS485.
USB port
ISOLATION
4000 for the Input.
1500 between output RS485 and the power supply.
EMC
For Industrial environments.
Immunity EN 61000-6-2.
Emission EN 6100-6-4.
EN 61010-1
HOUSING
Material self-extinguishing
3.9" x 4.4 " x 0.68"
100 x 112 x 17.5mm
Weight 3 oz 90 g
TEMPERATURE
Operating Temperature 5°F +149°F -15°C +65°C
Storage Temperature -40°F +185°F-40°C +85°C
Humidity (non condensing) 0-90%

 

Specifications

Input:Current 10 Amp.
 Voltage 600AC/100DC, 60AC/100DC.
Output: Modbus RS485
Analog 4-20mA, 0-20mA, 0-10V.
Digital Alarm or Pulse.
Power Supply: 9 to 30 Vdc.
Power Consumption: 1.3 W max.
Temperature rating: Operative 14°F +140°F - 15°C +65°C
  Storage Temperature - 40°F +185°F - 40°C +85°C.
Humidity: (non condensing) 0-90%.
Housing: Material Self-extinguishing.
Dimensions: 3.9" x 4.4 " x 0.68"
100 x 112 x 17.5mm
Weight: Weight 3 oz 90 g
EMC. For industrial environments.
  Immunity: EN 61000-6-2.
  Emission: EN 61000-6-4.
Configuration: DIP Switch Configurable.

Drawings

Power Supply  
Positive Pin 16
Negative Pin 17
Output Modbus  
GND Pin 32
B- Pin 33
A+ Pin 34
Input Current 
Terminal 1 and Terminal 6
Voltage 
Terminal 2 and Terminal 8
Output Digital
Terminal 25
Terminal 26
Output Analog
Terminal 29
Terminal 30
Terminal 31

Single Phase Power Datalogger wiring diagram


Applications

  • Single Phase Power Datalogger.
Back to General Description