Hart Intrinsic Safety Barrier.
Obsolete Product.

DAT5030ISAH

Range of ATEX Zener Barriers
Hart Hazardous Area Current loop Repeater.
• HART Intrinsic Safety Barrier.
• Protection mode II (1) G D [Ex ia] IIC-[Ex iaD].
• Input Current.
• Output 4-20mA and 0-10V
• Current Loop Repeater.
• DIP Switch Configurable.
• DIN Rail Mounted.
General Description

The Hart Intrinsic Safety Barrier current loop repeater DAT5030ISA Hart is a DIN Rail mount signal repeater. The input is Current loop and output can be either Current loop or Voltage. The input can be Active or Passive power supply meaning the excitation voltage can be supplied by the field equipment or the loop can be powered be the DAT5030ISA Hart. Also the output can either be Active or Passive but with the additional output ranges of 0-10V or 2-10V. There is also an auxiliary power supply of 15 Volts on the input side and an auxiliary power supply of 12 Volt on the output side.
The DAT5030ISA Hart is accurate to 0.1% full scale and has less than 0.01%/°f thermal drift.
The DAT5030ISA Hart also provides an isolation of 2000Vac between the input and output signal, and an isolation of 1500Vac between the power supply and the output signal.
This eliminates the effects of any ground loops and allows the use of the transmitter in heavy environmental conditions found in industrial applications. The DAT5030ISA Hart is in compliance with the standard 89/336/CEE on the Electromagnetic Compatibility.
The DAT5030ISA Hart is housed in a plastic enclosure of 22.5 mm thickness suitable for DIN rail mounting in compliance with EN-50022 and EN-50035 standards.

INPUT OUTPUT POWER SUPPLY
HART Current 4-20mA, 0-20mA. Power Supply Voltage 18-30Vdc
Current 4-20mA, 0-20mA. Voltage 0-10V, 0-5V, 2-10V, 1-5V. Reverse polarity protection 60Vdc
CURRENT CONSUMPTION CONFIGURATION ISOLATION
Between 80 and 120 mA DIP Switch Programmable Between Input/Comms/Power Supply 2000Vac.
EMC HOUSING TEMPERATURE
For Industrial environments Material self-extinguishing Operating Temperature -4 °F +140°F -20°C +60°C
Immunity EN 61000-6-2 Dimensions W x H x T 4" x 4 3/4" x 3 /4" Storage Temperature -40°F +185°F -40°C +85°C
Emission EN 6100-6-4 100 x 120x x 22.5 mm Humidity (non condensing) 0-90%
Weight 3 oz 100 g

Specifications

Input: HART 4-20mA, 0-20mA..
Output: Voltage 0-10V, 2-10V.
HART Current 4-20mA, 0-20mA.
Power Supply: 18 to 32 Vdc. Reverse polarity protection 60 Vdc.
Current Consumption: Current output 35 mA max. Voltage output 25 mA max.
Temperature rating: Operative -4°F +158°F -20°C +70°C
  Temperature Storage Temperature -40°F +185°F -40°C +85°C.
Humidity: (non condensing) 0-90%.
Housing: Material self-extinguishing.
Dimensions: 3 1/2" x 4 1/2 " x 1/2", 90 x 112x x 12.5 mm.
Weight: 3 oz 90 g.
EMC. For industrial environments.
  Immunity: EN 61000-6-2.
  Emission: EN 61000-6-4.
Configuration: PC Configurable and DIP Switch Configurable
Drawings

Signal Inputs

Input  
mA Passive Terminals + 4 and - 6
mA Active Terminals + 6 and - 5
Output  
mA Active Terminals + D and - A
mA Passive Terminals + A and - C
Voltage Terminals + B and - C
Power supply Positive +V J Negative -V I
Hart Intrinsic Safety Barrier wiring Diagram.
Applications
Back to General Description